Fenner in the Media

Understanding FRAS Conveyor Belts: Safety in Extreme Environments

Conveyor belts operate in some of the harshest conditions imaginable. Mining environments and applications often include high temperatures, sparks, combustible chemicals, frictional heat, and many other materials or situations that can lead to fires.

When a fire breaks out, conveyor belts can act as a pathway for flame propagation, spreading fire across the system and the site, posing catastrophic risks to people and operations.

To reduce this risk, conveyor operators can install Flame-Resistant and Anti-Static (FRAS) belting. Fenner Conveyors offers a range of FRAS cover compounds designed to meet stringent safety standards while delivering durability and performance.

What Does Anti-Static Mean?

Static electricity can build up on conveyor belting, and when a critical level is reached, that static electricity can discharge, acting as an ignition point for a fire or explosion. Anti-static goods are products that help prevent this discharge by dissipating the static electricity.

The anti-static performance of conveyor belt materials is affected by the presence of some mineral fillers and fire retardants, which is why quantifying the electrical resistance of fire-resistant conveyor belt covers is particularly important.

That’s why Fenner incorporates additional anti-static properties into our fire-resistant compounds, ensuring compliance with Australian and international standards for hazardous environments. Fenner general-purpose conveyor belt compounds are also all anti-static.

While most cover types are anti-static by default, compliance should always be verified through independent, reputable parties.

Common Misconceptions About FRAS Belting

Grade Matters

Fire Resistant Anti-Static (FRAS) refers to materials that have inherent flame-resistant and anti-static properties, and often those materials have local standards outlining the performance requirements in fire and static conductivity testing. FRAS covers a range of belts with varying durability, fire resistance, and anti-static properties.

FRAS is not a catch-all term, although it often is used as one. In Australia it is defined as compliance to testing requirements specified within TRG3608 although the term FRAS is often used to describe conveyor belts that are compliant to other standards. There are varying levels of fire resistance and durability and it is worth noting that in general the more stringent the test requirements, the higher the cost of the product.

Fire Resistance Applies to the Entire Belt

If only the top cover was fire-resistant, ignition can still pose a risk with combustible pulley cover or carcass compounds. Fenner Conveyors belting is tested for fire resistance throughout the product, with the carcass tested separately from the belt covers to quantify its flammability after heavy use, damage, or abrasion leading to the exposure of the reinforcement.

FRAS Doesn’t Guarantee Compliance for All Applications

It’s important to note that fire-resistant does not mean flame-proof. Removing an ignition source should result in a FRAS material self-extinguishing; however, prolonged exposure to flame will still cause fire resistant conveyor belting to burn and degrade.

There are many grades that can be considered FRAS, and it is important to define the regulatory and compliance requirements for the intended application. Belts must also meet standards for durability, impact resistance, and abrasion resistance to produce a suitable service expectation.

Fenner's FRAS Belt Range

Fenner offers three grades of our proprietary FRAS compound, FireBoss, each suited to different applications:

FireBoss S

  • Ideal for heavy-duty underground coal mining (AS4606 compliant – see below)
  • Complies with:
    • Full Scale Gallery – AS1334.12
    • Drum Friction – AS1334.11
    • Static Conductivity – AS1334.9
    • Small Scale Burn – AS1334.10
    • Oxygen Index Requirement – ISO4589
  • Exceeds all other S-Grade compounds in fire-retardant and anti-static properties
  • Designed for hazardous environments and explosive atmospheres
  • Excellent abrasion resistance (typical loss: < 70 mm³)
  • Independently tested, registered, and verified for compliance

FireBoss K

  • Entry-level fire-retardant and anti-static properties
  • Small Scale Burn and Static Conductivity compliant (ISO433)
  • Superior performance in high impact cut and gouge applications
  • Suitable for general applications requiring a moderate level of fire resistance such as coal preparation, power generation, sugar, and fertilizer

FireBoss EF

  • Superior fire-retardant and anti-static properties
  • Similar to AS4606 without the independent verification and gallery testing
  • Can be tailored for light or heavy-duty applications
  • Compliant with AS1332 and AS1333 standards
  • Suitable for applications requiring an increased level of fire resistance such as limited access tunnels, grain sheds, train load out stockpile conveyors, enclosed environments, and other similar applications.

How FRAS Belts are Tested

FRAS belts undergo multiple tests to cover different flame or belt operational situations, so several tests are used. This section will outline the typical methods used for each classification of belt listed above:

AS4606 – Grade S

Composed of five individual tests to assess the level of performance and requires independent NATA accredited testing with governing body registration and independent verification.

Gallery Fire Test (AS-1334.12) – “Tunnel Test”

In the Gallery Fire test, the potential hazard of a belt being ignited from a continuous external flame source is quantified, as well as the ability of the product to resist spreading the fire to other areas (referred to as fire propagation). This hazard is assessed by using a sample belt length of 2 m supported horizontally on a steel trestle placed in a chamber resembling that of a mine tunnel. This is also why this test has the nickname “tunnel test.”

A continuous flow of air is drawn in through the chamber while the sample is subjected to a controlled flame from a propane burner located under the sample. Upon the flame’s removal, the belt is allowed to continue to burn and glow until cessation of flame, and the total length of undamaged belt is quantified by physical measurement.

Passing this test requires a portion of undamaged belt to be measured after all flames and glowing material have ceased.

Drum Friction Test (AS-1334.11)

This test examines the dangers associated with a stalled belt and a driven rotating drum or pulley resulting in friction heat build-up. A test piece of conveyor belting is mounted and tensioned under an applied load to keep it in a stationary position as it is wrapped halfway around a rotating drum pulley.

The test is continued at specific tensions in the Australian standard until the belt breaks or for two hours whichever occurs first in still or moving air depending on the testing conditions. The presence or absence of flame and glow is noted, and the temperature of the drive drum is measured. Exceeding the maximum permissible temperature, burning, or glowing are all failure conditions for the test.

Small Scale Burn (AS-1334.10) – “Finger Burn”

The “Finger Burn” test, as it is commonly known in the industry, uses a small, finger length sample to check the likelihood of a conveyor belt ignition from a relatively small ignition source in a standard atmosphere. The end of a horizontally oriented belt sample is subjected to a “Bunsen” type flame for a given time period.

Following the removal of the flame and exposure to an air current, the duration of the continued burning present on the belt is noted, as well as any afterflame and afterglow.

For K-Grade, this test is conducted in a slightly different fashion, comprising a vertically held sample being exposed to the Bunsen flame with the burner positioned at an angle.

Passing the test requires belts to meet time thresholds for self-extinguishing.

Electrical Conductivity Test (AS-1334.9) – “Static”

The potential build-up of material and subsequent discharge of static electrical charge on moving conveyors can result in ignition or even explosion in certain environments. Electrical resistance is determined in this test by passing a current at a specified voltage between electrodes placed on a suitably prepared belt surface.

The resistance of the belting between the electrodes is measured after a given time. The internationally recognized acceptance criteria for electrical conductivity is a maximum resistance of 3 × 10⁸ Ohms. Fenner FRAS rubber compounds are formulated to ensure that those products are sufficiently conductive to avoid build-up of static electricity.

Oxygen Index Requirement Test (ISO-4589)

A very common test for rubber and plastic components, this process tests the material for oxygenation levels required in the atmosphere to maintain combustion.

A sample is placed inside a controlled test chamber where oxygen and inert gas levels can be modulated. When a flame is exposed to a sample in the controlled atmosphere, the duration of the burn is measured and quantified as a pass or fail for a given oxygen level. Subsequent samples are then tested across various oxygen levels to gather a range of results of passes and failures. An equation is then applied to these results to determine the material’s Oxygen Index in a percentage value.

This test is useful for quality control purposes as it provides a bench scale method for determining fire-retardant values for materials that don’t readily burn in a standard atmosphere.

Key Considerations

Fire hazards depend on belt characteristics, material, installation, and operating environment. Australian and international standards differ in flame test requirements, and underground coal mining belts require statutory approval.

In Summary

FRAS conveyor belts are essential for operations in environments where flammable substances pose a risk. Understanding what FRAS means, how it’s tested, and common misconceptions will help you select the right belt for your site and ensure compliance with safety standards.

Need help choosing the right belt? Contact our team today; we’re here to assist.

Related Stories